Odyssey
Odyssey with Fractional CO2 Laser
The Fractional CO2 laser with Odyssey trade-mark operates by creating 100 micrometer columns of laser beam in the skin align with the ability to adjust the number of laser beam dots.
The Odyssey delivers the laser energy to the target tissue by using a particular double part pulse called Smart Pulse.
In the first step, a high power Ablative pulse with short duration leads to micrometer destruction of tissue which delivers the laser energy into the optimum depth of tissue.
In the second step, a low power pulse with long duration delivers the required thermal energy into the depth of tissue and leads to new vascularization and collagen remodeling by stimulating the fibroblasts of the tissue.
Therefore, by manipulation of this technology, we will gain high quality and long lasting restoration of the tissue.
Moreover, there will be no damage to the tissue and the risk of complications will be drastically diminished.
General Surgery Indication
- Corns, Warts etc
- Freckles
- Birthmarks(mole)
- Skin resurfacing
- Phimosiectomy
- Tumor elimination
- Hemorrhoids and anal fistulas
- Fine wrinkle
- Condyloma
- Syringoma
- Snoring
- Automatic LVR
Dental Surgery Indication
- The second implant operation
- Hyper sensitive
- Hemostasis after dental extraction
- Herpetic gingivitis
- Crown lengthening
- Frenulum excision
- Gingival excision
- Gingival plastic operation
- Cleaning of dental cuticle cyst
- Removal of pigmentation
- Pulp capping -Fluorine coating
- Allergic splenitis
- Sterilization in paradental cyst
- Sterilization in root canal
- Abscess treatment
Fractional Surgery indication
- Skin tightening
- Wrinkle
- Large pore
- Acne scar
- Skin resurfacing
- Stretch mark
- Laser peeling
- Rubbing mode
- Pudenda
- Manual LVR
- Age Spot
Specification
Model | Odyssey | |
Laser Type | CO2 Laser / RF CO2 Laser (USA Origin) | |
Wave length | 10.600nm | |
Laser power | 1-40W | |
Function | ||
Aiming Beam | Diode Laser 655nm (5mw) :1-10 Step | |
Surgical Mode | Handpiece Type | 50mm,100mm(Basic) E.N.T & Dental Handpiece (Optional) |
Laser Operation Mode | 1. CW 2. Normal Pulse 3. Super Pulse 4. Super Pulse Continuous 5. Ultra Pulse 6. Smart Protocol(General Surgery/Dental Surgery) |
|
Pulse Duration | – Ultra Pulse: 100us-900us – Super Pulse: 1,0-4,5ms – Normal Pulse: 5-20ms |
|
Repeat Time | OFF, 2ms/500ms adjustable, 5ms, 10ms, 30ms, 50ms, 70ms, 100ms, 250ms, 500ms | |
Fractional Mode Smart Pulse |
Beam Mode | Ultra Pulse |
Density Level | (0,2-2,6)25 Step(x,y line) ; 1dots-10201 dots | |
Operation Mode | Fractional Mode | |
Beam Patterns | Array, Spray, Random | |
Beam Size | 70~100um/2x2mm – 20×20mm | |
Beam Shape | ![]() ![]() ![]() ![]() |
|
Depth Level | 1-5 Step | |
Handpiece | – Fractional Handpiece(Galvanic Motor) – Vaginal Rejuvenation Handpiece(Optional) |
|
Repeat Time | 0.2~2.0sec, single(OFF) |
General Features
Electrical Requirements | 220v, 6A. single phase,50/60hz |
Cooling System | Air cooling |
Dimensions | 500(w)x390(d)x1120(H)mm |
Weight | 60kg |
Display | 10.1 inches color LCD |